Water or Steam Boiler Repair

Dye Plumbing & Heatingstarstarstarstarstar4.8 / 5

379 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Water Or Steam Boiler Repair Laporte, Indiana

If your heating system in Laporte, IN is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in Laporte, IN. Dye Plumbing & Heating service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly.

Get Your Quote Today



Dye Plumbing & Heating Water Or Steam Boiler Repair Laporte, Indiana



Recent Water Or Steam Boiler Repair Laporte, Indiana by Dye Plumbing & Heating

Water Or Steam Boiler Repair Laporte, Indiana
Technician Invoice Notes: Call For Boiler Leaking Water. Upon Arrival Found Relief Valve Discharging And Steam Coming From Auto Air Vent. Found Boiler Temperature Well Above Aquastat Setpoint, Fill Trol Expansion Tank Failed And Pilot Light Out. Suspect Gas Valve To Have Stuck In The Open Position Causing The Boiler To Overheat. Gave Client The Option For All New Replacement Components Or Option To Replace The Boiler Due To The Unknown Integrity Of The Boiler Heat Exchanger. Replaced Main Aquastat Relay Control, Replaced Gas Valve, Replaced Fill Valve, Replaced Expansion Tank And Replaced Relief Valve. Filled And Purged System Of Air. Cycled Boiler From Both Thermostats And Zone Valves And Observed Unit Operation. All Radiation Is Heating At This Time And The Boiler Cycles Off At 180° With A Pressure Of Approximately 17 PSIG. Circulator Pump Bearings Are Slightly Noisy Although Pump Is Operational At This Time. Client Understands That The Boiler Is Past Its Life Expectancy.
LAPORTE, IN
04-20-2022

Water Or Steam Boiler Repair Laporte, Indiana
Technician Invoice Notes: Call For Intermittent Heat. Upon Arrival Found Thermostat Set Point At 75° And 68° In The Home. After Further Investigation Found Furnace In Lockout Due To High Limit Fault. Found Air Filter Plugged. Replaced Client Provided Air Filter And Cycled Furnace In Low And High Stages To Ensure Proper Operation. Unit Is Heating Properly At This Time With Rise Of 55 Degrees.
LAPORTE, IN
03-19-2021

©MPN Media & Marketing 2024