We install and service all brands of central air conditioning and cooling systems in Laporte, IN. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Laporte, IN.

Let us help you decide how best to solve your air conditioning needs today.

Get Your Quote Today



Dye Plumbing & Heating AC Cooling And Air Conditioning Systems Laporte, Indiana



Recent AC Cooling And Air Conditioning Systems Laporte, Indiana by Dye Plumbing & Heating

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details: EQUIPMENT: Armstrong 4SCU13LB130P-6; SERIAL: 1622E16875 Series Outdoor Condensing Unit - 13 SEER Efficiency Rating Armstrong EAU1P30B-50; SERIAL:6022C0721 Series Indoor Evaporator Coil SCOPE OF WORK: 1. Remove And Dispose Of The Existing Indoor Evaporator Coil, Copper Refrigeration Piping And Outdoor Condensing Unit. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. 3. Provide And Install The New Outdoor Condensing Unit In The Specified Location On A Field Supplied Composite Pad. - Bring In New Fill Dirt For The Condensing Unit. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit Providing A New Electrical Whip And Fused Disconnect. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drainage Piping From The New Evaporator Coil. 7. Start The New Equipment And Check System Operations.
LaPorte, IN
07-28-2022

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details: Heil Package Air Conditioner Model PAJ430000KTP0B; Serial: F203555708 Heil Square To Round Duct Adapter Re-use Existing Thermostat SCOPE OF WORK: 1. Remove And Dispose Of The Existing Air Conditioner. 2. Install The New Air Conditioner In The Same Location Adapting To The Existing Supply & Return Air Duct Work. The Existing Duct System Travels Underground And The Condition/usability Of The Duct Is Unknown At This Time. This Proposal Does Not Include Duct System Replacement Or Repair. If Duct Repairs Or Replacement Is Necessary, Dye Plumbing & Heating Will Provide Recommendations And Pricing To Complete The Work. 3. Adapt The New Unit To The Existing Electric Circuit. Replace The Flexible Conduit From The Disconnect To The New Unit. 4. Start The New Unit And Check Operation.
LaPorte, IN
07-14-2021

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details: Heil Package Air Conditioner Model PAJ430000KTP0B; Serial: F203555708 Heil Square To Round Duct Adapter Re-use Existing Thermostat SCOPE OF WORK: 1. Remove And Dispose Of The Existing Air Conditioner. 2. Install The New Air Conditioner In The Same Location Adapting To The Existing Supply & Return Air Duct Work. The Existing Duct System Travels Underground And The Condition/usability Of The Duct Is Unknown At This Time. This Proposal Does Not Include Duct System Replacement Or Repair. If Duct Repairs Or Replacement Is Necessary, Dye Plumbing & Heating Will Provide Recommendations And Pricing To Complete The Work. 3. Adapt The New Unit To The Existing Electric Circuit. Replace The Flexible Conduit From The Disconnect To The New Unit. 4. Start The New Unit And Check Operation.
LaPorte, IN
07-14-2021

AC Cooling And Air Conditioning Systems Laporte, Indiana
SCOPE OF WORK: 1. Remove And Dispose Of The Existing Evaporator Coil, Condensing Unit And Accessible Copper Refrigeration Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. 3. Provide And Install The New Outdoor Condensing Unit In The Same Location On A Field Supplied Composite Pad. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect Providing A New Electrical Whip. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit Through The Client Provided Trench. - This New Refrigeration Piping Shall Be Insulated And Wrapped Before Covered. 6. Install New Condensate Drainage Piping From The New Evaporator Coil Adapting To The Existing Condensate Piping. 7. Start The New Equipment And Check System Operation.
LAPORTE, IN
06-15-2021

AC Cooling And Air Conditioning Systems Laporte, Indiana
EQUIPMENT: Armstrong 4SCU13LE130 Series Outdoor Condensing Unit - 13 SEER Efficiency Rating - High And Low Safety Pressure Switches - Insulated Sound Blanket To Help Reduce Operating Noise Armstrong 30BXCA Series Indoor Evaporator Coil SCOPE OF WORK: 1. Remove And Dispose Of The Existing Evaporator Coil, Condensing Unit And Copper Refrigeration Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. 3. Provide And Install The New Outdoor Condensing Unit In The Same Location On A Field Supplied Composite Pad. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect Providing A New Electrical Whip. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drainage Piping From The New Evaporator Coil To The Nearby Floor Drain. 7. Start The New Equipment And Check System Operation. 8. Provide And Install A New Whole House Water Filter On Existing Housing. All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty.
LaPorte, IN
05-27-2021

AC Cooling And Air Conditioning Systems Laporte, Indiana
SCOPE OF WORK: 1. Remove And Dispose Of The Existing Evaporator Coil, Condensing Unit And Copper Refrigeration Piping. 2. Provide And Install The New Evaporator Coil In The Same Location Adapting To The Existing Furnace And Supply Air Duct Work. 3. Provide And Install The New Outdoor Condensing Unit In The Same Location On A Field Supplied Composite Pad. 4. Adapt The New Condensing Unit To The Existing Electrical Circuit Providing A New Electrical Whip And Service Disconnect. 5. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit. 6. Install New Condensate Drainage Piping From The New Evaporator Coil To The Existing Condensate Pump. 7. Start The New Equipment And Check System Operation.
LAPORTE, IN
05-12-2021

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Attic Exhaust Fan Not Operating. Upon Arrival Found Attic Thermostat/humidistat Receiving Power And Fan Motor Not Responding. After Further Investigation Found Failed Attic Fan Motor.
LAPORTE, IN
08-06-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Started A/C System As Part Of HVAC Contract Installation. Adjusted Indoor Blower Speed For 1000 CFM And Adjusted Refrigerant Charge With An Additional 10 OZ Of R-410A Refrigerant. Filled Condensate Pump To Ensure Proper Operation And System Is Cooling Properly With A Temperature Drop Of 16 Degrees Across The Evaporator Coil.
LaPorte, IN
05-20-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Moisture At Base Of Wall In Kitchen Behind Refrigerator. Camera Inspected Through Small Hole But Unable To Locate Source. Camera Inspected Through Shower Valve Hole In Second Floor Bath And In Joist Space Under Shower. Unable To Locate Source. Removed Sections Of Drywall Behind Refrigerator To Identify Location Of Leak. Due To A False Ceiling Unable To Make Repairs From Kitchen Side. Removed Section Of Wall In Shower Alcove On Opposite Side Of Wall To Expose 3/4” Copper Piping Failure Location. Removed Leaking Copper Tee And Surrounding Piping. Replaced With New Copper Piping And Fittings.
LaPorte, IN
04-11-2020

starstarstarstarstar
5 Star Rating
AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Boiler Relief Valve Dripping. Upon Arrival Found Boiler Pressure At 20 PSIG And 180° With Evidence Of Relief Valve Leaking. Inspected Expansion Tank And Auto Fill Devices. Replaced Relief Valve And Purged Air From Boiler. Secured Bypass Handle Of Reducing Valve To Help Prevent The Possibility Of Accidental Over Pressurization Of The Boiler. Cycled Boiler To 180° And Found Unit Cycle Off At 19 PSIG. System Is Operating Properly At This Time With No Leaks Present.
LaPorte, IN
04-11-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Thermostat Calling For Heat With No Low Voltage. After Further Investigation Found Failed Transformer. Client Had Switched To A/C On The Thermostat Recently And The Furnace Never Came Back On. Found Rodent Chewed Wired At Outdoor Condenser. Repaired Low Voltage Wiring And Re-sealed Line Set Hole. Inspected Furnace Heat Exchanger And Found The Primary Cells Failed. Performed A Carbon Monoxide Test And Unit Is Emitting No Carbon Monoxide At This Time. Highly Recommended Client To Replace Furnace Due To The Potential For Carbon Monoxide Gases.
LaPorte, IN
04-11-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Investigated And Found Basement Toilet To Have A Broken Fill Valve. Replaced Toilet Tank Components. Set Proper Water Level And Cycled To Test Operation.
LaPorte, IN
04-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Technician Invoice Notes: Call For Main Circulator Pump Leaking. Upon Arrival Found Failed Bearing Assembly In Main B&G Pump. Replaced Pump Assembly With New Taco Circulator And Cycled Boiler To Ensure Proper Operation. System Is Heating Properly At This Time. Recommend Having The Other Two Circulator Pumps Replaced Due To Noisy Operation And Having Boiler Serviced Annually For Preventative Maintenance Purposes.
LaPorte, IN
04-10-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Installation Details:EQUIPMENT:Armstrong Model: A96UH2E070B12S-01; Serial: 5919M00951 Series High Efficiency Furnace- 96% AFUE Efficiency Rating- Two Stage Operation- Stainless Steel Heat Exchangers- ECM Constant Torque Blower MotorSCOPE OF WORK:1.Remove And Dispose Of The Existing Furnace And Condensate Drain Piping.2.Provide And Install The New Furnace In The Same Location Adapting To The Existing Supply & Return Air Duct Work. 3.Adapt The New Furnace To The Existing Line Voltage And Low Voltage Electrical Circuits.4. Adapt The New Furnace To The Existing Gas Supply Piping.5. Adapt The New Furnace To The Existing PVC Intake & Exhaust Vent Piping. - Terminate The Exhaust Piping Per Manufactures Instructions.6. Provide And Install New Condensate Drainage Piping From The New Furnace And Existing A/C Evaporator Coil.7. Adapt The New Furnace To The Existing Thermostat.8. Start The New Equipment And Check System Operation. - Ensure Proper Airflow Selections Have Been Made For The Cooling And Heating Cycles Of The Equipment.All Equipment Warranties Per The Terms And Conditions Of The Manufacturer. Armstrong Equipment For This Application Qualifies For A Ten Year Limited Parts Warranty With A Standard Twenty Year Parts Warranty On The Heat Exchangers. Please Review All Manufacturer Warranty Certificates For Full Details Of Warranties.Dye Plumbing & Heating Warranty: We Offer A Two Year Material And Labor Warranty For The Work Provided. This Warranty Does Not Include Standard Maintenance Procedures (annual Cleaning, Filter Changes, Etc).
LaPorte, IN
04-01-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Upon Arrival Found Kitchen Sink With Standing Water In Drain. Augered Kitchen Sink Drain. Reassembled Trap Way And Ran Large Amount Of Water To Flush Line And Test Operation. Observed Proper Flow.
LAPORTE, IN
03-23-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Located Underground Sewer Piping Near House Outdoors. Excavated Area And Unearthed Pipe. Found Cast Iron Separation Near Foundation. Removed Section Of Disjointed Piping To Area With Proper Pitch. Installed New 4” Pvc Piping And Clean Out. Flushed Toilet And Ran Water In Fixtures. Observed Proper Flow Through Repaired Piping. Backfilled Site And Bedded Piping.
Laporte, IN
03-23-2020

AC Cooling And Air Conditioning Systems Laporte, Indiana
Performed Water Heater Flush And Cleaned Combustion Components. Install One New Full Port Brass Ball Valve For Future Maintenance.
LaPorte, IN
03-17-2020