Gas Furnace Maintenance

Dye Plumbing & Heatingstarstarstarstarstar4.7 / 5

497 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Gas Furnace Maintenance Laporte, Indiana

Are you looking for gas furnace maintenance in Laporte, IN ? Our heating and furnace service technicians have years of experience working on furnaces like yours in Laporte, IN. Dye Plumbing & Heating has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

We offer gas furnace maintenance and maintenance agreements to keep your heating system running great. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace Maintenance Agreements in Laporte, IN

Get Your Quote Today



Dye Plumbing & Heating Gas Furnace Maintenance Laporte, Indiana



Recent Gas Furnace Maintenance Laporte, Indiana by Dye Plumbing & Heating

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Boiler System. Cleaned Burners, Cleaned Pilot Assembly, Drained Expansion Tank, Tested Reducing Valve, Tested Relief Valve, Cleaned Inducer Signal Port, Inspected Heat Exchanger Sections And Cycled Boiler System From All Three Zones To Ensure Proper Operation. System Cycles Off At 180 Degrees With A Pressure Of Approximately 16 Psi. Client Requests A Mailed Receipt.
LaPorte, IN
10-22-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service And Clean. Inspected Heat Exchangers Finding No Failures At This Time. Inspected Blower Wheel, Air Filters And Evaporator Coil. Measured Ignitor Resistance At 74 Ohms. Both Blower Motor And Inducer Motor Are Operating Within Manufactures Specs. Cleaned Flame Sensor, Inspected Burners And Crossovers. Cleared Inducer Signal Port And Drain Lines. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 55°. Checked For Carbon Monoxide Finding 0ppm At This Time.
LAPORTE, IN
10-22-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service And Clean. Inspected Heat Exchangers Finding No Failures At This Time. Primary Heat Exchanger Cells Are Showing Extreme Signs Of Fatigue. Recommend Customer Getting Carbon Monoxide Alarm. Cleaned Flame Sensor And Inspected Burners. Cleared Inducer Signal Port And Drain Lines. Measured Ignitor Resistance At 75 Ohms. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 65°. Recommended Regular Check Ups To Customer.
LAPORTE, IN
10-22-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service And Clean. Inspected Heat Exchangers Finding No Failures At This Time. Primary Heat Exchanger Is Showing Signs Of Fatigue. Cleaned Flame Sensor, Spark Ignition Components And Burners. Cleared Inducer Signal Port, Drain Lines And Trap. Inspected Blower Wheel, Evaporator Coil And Replaced Customer Provided Air Filter. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 55°. Tested For Carbon Monoxide Finding 0ppm At This Time.
LAPORTE, IN
10-22-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 52 Ohms And Cleaned Condensate Trap. Inspected Blower Wheel, Inspected EAC And Inspected Evaporator Coil. Cycled Unit From The Thermostat To Ensure Proper Operation. Unit Heating Properly At This Time With A Temperature Rise Of 56 Degrees On Low Stage And 65 Degrees On High Stage.
LaPorte, IN
09-17-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service Per Membership Agreement. Inspected Heat Exchangers Finding No Failures At This Time (there Are Slight Signs Of Fatigue). Inspected Blower Wheel, And Air Filter. Cleared Condensate Trap And Inducer Signal Port. Cleaned Flame Sensor And Inspected Burners. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 46° Low Stage And 60° High Stage.
LAPORTE, IN
09-17-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service Per Membership Agreement. Inspected Primary And Secondary Heat Exchangers Finding No Failures At This Time But Primary Heat Exchanger Is Showing Extreme Signs Of Fatigue (extreme Pitting/rust Marks On Lower Primary Heat Exchanger Cells). Cleaned Flame Sensor, Inspected Burners And Crossovers. Cleared Drain Line, Inducer Signal Port And Condensate Trap. Ignitor 58 Ohms. Cycled Furnace To Insure Proper Operation. System Is Heating Properly At This Time With A Temperature Rise Of 60°. Completed A Carbon Monoxide Test Finding 0ppm At This Time. Recommended Customer Getting A Carbon Monoxide Alarm.
LAPORTE, IN
09-17-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service And Clean. Inspected Heat Exchangers Finding No Failures At This Time (rust Spots Beginning To Show On Lower Surface Of Primary Heat Exchanger). Cleaned Flame Sensor, Inspected Burners And Crossovers. Inspected Blower Wheel, Evaporator Coil And Air Filter. Cleared Inducer Signal Port, Condensate Trap And Drain Lines. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 46°.
LaPorte, IN
09-17-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service Per Membership Agreement. Inspected Heat Exchangers Finding No Failures At This Time. Inspected Blower Wheel, Air Filter And Evaporator Coil. Inspected Burners And Crossovers. Cleaned Flame Sensor. Cleared Inducer Signal Port And Drain Lines. Ignitor 47 Ohms. Inspected Humidifier And Pad. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 58°. Needs To Be Billed For USP Renewal.
LaPorte, IN
09-17-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service Per Plan Requirements. Cleaned Burners, Cleaned Flame Sensor, Cleaned Condensate Trap, Measured Igniter Resistance At 72 Ohms, Inspected Blower Wheel, Inspected Air Filter, Inspected Evaporator Coil, Inspected Primary And Secondary Heat Exchangers And Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 57 Degrees.
LaPorte, IN
09-17-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed USP Furnace Service Per Member Agreement. Inspected Primary And Secondary Heat Exchangers And Found No Failures At This Time. Cleaned Burners, Cleaned Flame Sensor And Cleaned Condensate Trap. Measured Igniter Resistance At 53 Ohms And Inspected Blower Wheel, Evaporator Coil And Air Filter. Also Replaced Humidifier Pad And Ensured Proper Unit Operation. Cycled Furnace From The Thermostat To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 50 Degrees.
LAPORTE, IN
09-14-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service Per Membership Agreement. Inspected Heat Exchanger Finding No Failures At This Time (signs Of Fatigue). Inspected Blower Wheel, Evaporator Coil And Air Filter. Cleaned Flame Sensor, Inspected Burners And Crossovers. Ignitor 67ohms. Cleared Inducer Signal Port. Inspected Furnace Exhaust. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 56°.
LAPORTE, IN
09-14-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service And Clean. Inspected Heat Exchangers Finding No Failures At This Time. Cleaned Burners Crossovers, And Flame Sensor. Cleared Drain Lines. Ignitor 18 Ohms. Inspected Air Filter And Blower Wheel. Performed Carbon Monoxide Test Finding 0 Ppm At This Time. Cycled Furnace From Thermostat To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 45°.
LaPorte, IN
09-14-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service. Inspected Heat Exchangers Finding No Failures At This Time. Inspected Blower Wheel, Evaporator Coil And Air Filter. Cleaned Burners, Crossovers And Flame Sensor. Cleared Inducer Signal Port, And Drain Lines. Ignitor 48 Ohms. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 56°.
LaPorte, IN
09-13-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Call To Service Furnace And Flush And Tune Water Heater. Serviced Furnace. Cleaned Burners, Cleaned Flame Sensor, Cleaned Inducer Signal Port, Measured Igniter Resistance At 17 Ohms, Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Primary Heat Exchanger Cells With No Confirmed Failures At This Time. Powered Humidifier Is Not Operational. Cycled Furnace To Ensure Proper Operation Unit Is Heating Properly At This Time With A Temperature Rise Of 55°. Also Found Vibration Inside Furnace. Suspect The Heat Exchanger Bracket To Be The Cause Of Rattling; No Actions Taken At This Time. Client Declined Water Heater Flush At This Time.
LaPorte, IN
02-02-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Furnace, Cleaned Burners, Cleaned Flame Sensor, Cleaned Condensate Trap, Cleared Drain Lines, Measured Igniter Resistance At 54 Ohms, Inspected Blower Wheel, Inspected Evaporator Coil, Inspected Air Filter And Inspected Primary And Secondary Heat Exchangers And Found No Failures At This Time. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 50°. Completed Carbon Monoxide Test Finding 0ppm At This Time.
LaPorte, IN
01-27-2021

starstarstarstarstar
5 Star Rating
Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Armstrong Furnace, Cleaned Burners, Cleaned Flame Sensor, Cleaned Spark Ignition Components, Cleaned Pilot Assembly, Cleared Condensate Trap, Inspected Blower Wheel, Inspected Evaporator Coil, Replaced Air Filter And Inspected Primary And Secondary Heat Exchangers With No Confirmed Failures At This Time. Cycled Furnace To Ensure Proper Operation And Found Inducer Motor Bearings Weak. Unit Is Heating At This Time With A Temperature Rise Of 51°. Client Requests Estimates For A Replacement Inducer Motor Assembly And A Replacement Furnace. Serviced Bryant Furnace, Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 58 Ohms, Cleaned Condensate Trap, Inspected Blower Wheel, Inspected Evaporator Coil, Replaced Air Filter And Inspected Primary And Secondary Heat Exchangers With No Failures At This Time. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of Degrees.
LAPORTE, IN
01-04-2021

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Furnace, Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 72 Ohms, Checked Blower Wheel, Checked Evaporator Coil, Checked Air Filter, Cleaned Condensate Trap, And Inspected Primary And Secondary Heat Exchangers; Found No Failures At This Time (primary Heat Exchanger Is Showing Signs Of Fatigue). Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 55 Degrees. Completed Carbon Monoxide Test Finding 0ppm At This Time. Also Took Amp Readings On Inducer And Blower Motors, Both Are Operating Within Manufactures Specs.
LAPORTE, IN
12-29-2020

Gas Furnace Maintenance Laporte, Indiana
Serviced Furnace For Season
LaPorte, IN
12-22-2020

starstarstarstarstar
5 Star Rating
Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Furnace Overheating With Extremely Poor Airflow. Found Pleaded Filter Restricting Airflow By Over 50%. Replaced Pleaded Air Filter With High Flow Filter. Recommended To Customer To Cease Using Pleaded Air Filters. Inspected Furnace For At Least 30 Minutes To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 53°.
LaPorte, IN
12-18-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service. Inspected Blower Wheel, Evaporator Coil And Air Filter. Inspected Heat Exchanger Cells Finding No Failures At This Time. Cleaned Flame Sensor, Burners And Crossovers. Cleared Drain Line, Condensate Trap And Inducer Signal Port. Igniter 50 Ohms. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 44° Low And 53° High. Also Completed Carbon Monoxide Test Finding 0ppm At This Time.
LAPORTE, IN
12-16-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service. Inspected Blower Wheel, Air Filter And Evaporator Coil. Inspected Heat Exchanger Finding No Failures At This Time. Cleaned Burners And Crossovers. Cleaned Flame Sensor And Vents. Cleared Inducer Signal Port. Igniter 85 Ohms. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 59°. Completed Carbon Monoxide Test Finding 0ppm At This Time.
LaPorte, IN
12-10-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Furnace, Cleaned Burners, Cleaned Flame Sensor, Cleaned Inducer Motor And Vent, Measured Igniter Resistance At 79 Ohms, Inspected Blower Wheel, Inspected Air Filter, Inspected Evaporator Coil And Inspected Heat Exchanger Cells With No Failures At This Time. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 56 Degrees.
LAPORTE, IN
12-08-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Furnace. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 80 Ohms, Inspected Blower Wheel, Inspected Evaporator Coil And Replaced Client Provided Air Filter. Also Inspected Vent And Inducer Assembly, Cleaned Inducer Signal Port And Inspected Primary Heat Exchanger Cells. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 65 Degrees.
LAPORTE, IN
12-08-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Usp Furnace Service. Inspected Blower Wheel, Evaporator Coil And Changed Customer Supplied Air Filter. Inspected Heat Exchangers Find No Failures At This Time. Inspected Burners And Crossovers, Cleaned Flame Sensor, Cleared Inducer Signal Port, Drain Lines And Condensate Trap. Took Amp Reading Of Blower Motor And Inducer Motor. Cycled Condensate Pump To Insure Proper Operation. Igniter Ohms 50. Furnace Is Heating Properly At This Time With A Temperature Rise Of 45° Low And 57° High. Completed Carbon Monoxide Test Finding 0ppm At This Time.
LAPORTE, IN
12-02-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Call For Furnace Short Cycling. Upon Arrival Cycled Furnace And Found Short Cycling On Pressure Switch Fault. After Further Investigation Found Inducer Signal Port Partially Obstructed. Cleaned Inducer Signal Port, Cleaned Burners, Cleaned Pilot Assembly, Inspected Blower Wheel, Inspected Air Filter, Inspected Evaporator Coil And Inspected Primary Heat Exchanger Assembly. Could Not Confirm Any Failures In The Heat Exchanger At This Time, Although It Does Show Signs Of Fatigue. Cycled Furnace Several Times From The Thermostat And Unit Is Heating Properly At This Time With A Temperature Rise Of 57° Also Performed A Carbon Monoxide Test And Unit Is Emitting No Carbon Monoxide Gases At This Time.
LaPorte, IN
11-20-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Furnace. Cleaned Burners, Cleaned Flame Sensor, Cleaned Condensate Trap, Replaced Hot Surface Igniter, Inspected Blower Wheel, Replaced Client Provided Air Filter And Inspected Primary And Secondary Heat Exchangers. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 50 Degrees.
LaPorte, IN
11-20-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Serviced Furnace. Cleaned Burners, Cleaned Flame Sensor, Cleaned Inducer Signal Port, Measured Igniter Resistance At 49 Ohms, Cleaned Vent Piping, Inspected Blower Wheel, Inspected Evaporator Coil, Inspected Air Filter And Inspected Heat Exchanger Assembly. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 58 Degrees.
LAPORTE, IN
11-20-2020

Gas Furnace Maintenance Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service. Cleaned Burners, Crossovers, Flame Sensor And Condensate Trap. Cleared Inducer Signal Port And Drain Lines. Cycled Condensate Pump. Inspected Blower And Heat Exchangers Finding No Failures At This Time (several Spots On Primary Heat Exchanger Starting To Flake And Show Signs Of Fatigue). Cycled Unit And Tested Operation. Unit Heating Properly At This Time With A Temperature Rise Of 54 Degrees. Igniter 40 Ohms. Completed Carbon Monoxide Test Finding 0ppm At This Time.
LaPorte, IN
11-20-2020