If your gas furnace in Union Mills, IN is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Union Mills, IN. Dye Plumbing & Heating has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.
We provide gas furnace service in Union Mills, IN
We provide gas furnace repair in Union Mills, IN
Furnace Service And Repair Union Mills, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Furnace Giving Code For Pressure Switch Stuck Open. Found Inducer Not Pulling Adequate In W.c When Running. Checked Exhaust Vent Finding No Obstructions. After Further Investigation Found Inducer Motor Rubbing Internally And Locking Up Occasionally. Checked Inducer Assembly Finding No Obstructions. Determined Bearing May Be Beginning To Fail. Found Cracked Port On Collector Box Which Appears To Have Been Leaking For Awhile Causing Rust In Blower Cabinet. Customer Wants Estimate For New Furnace.
Union Mills, IN
02-07-2024
Furnace Service And Repair Union Mills, Indiana
Technician Invoice Notes: Found Melted Wire At Wire Nut In Power Switch Box. Replaced Switch On Side Of Furnace And Repaired Wire. Tested Amp Draws Of Furnace And Condensate Pump. Cycled Furnace, Temperature Rise 41 Degrees, Furnace Operational At Departure.
Union Mills, IN
02-07-2024
Furnace Service And Repair Union Mills, Indiana
Technician Invoice Notes: Call For Humidifier Leaking. Upon Arrival Customer Stated They Wanted Humidifier Unhooked Because Of Leaking. After Investigation Found Furnace Doesn’t Have A Humidifier. Leaking Is Do To Failed Secondary Heat Exchanger. Shut Off Furnace At Stat And Warned Customer Of Dangers Of Carbon Monoxide If Ran. Gave Customer Replacement Options And Declined Repair Options From Us At This Time.
UNION MILLS, IN
01-28-2022
Furnace Service And Repair Union Mills, Indiana
Technician Invoice Notes: Call For No Heat From LB White Shop Heater. Upon Arrival Found Unit Attempting To Light And Locking Out Due To Ignition Failure. After Further Investigation Found Failed Gas Valve. Replaced Gas Valve And Converted Valve For Use With LP Gas. Tested Unit For Proper Operation. Also Serviced Armstrong Furnace. Cleaned Flame Sensor, Inspected Burners, Measured HSI Resistance At 47 Ohms, Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Heat Exchangers With No Failures At This Time. Also Inspected Humidifier Pad And Air Filter; Client Is To Replace Their Own Filters. Cycled Furnace To Ensure Proper Operation And Unit Is Heating Properly At This Time With A Temperature Rise Of 38° On Low Stage And 55° High Stage. Client Requests A Mailed Receipt.
Union Mills, IN
11-15-2021
Furnace Service And Repair Union Mills, Indiana
Technician Invoice Notes: Call For Reznor Radiant Tube Heater Not Working. Upon Arrival Found Failed Gas Valve. Replaced Gas Valve And Converted Valve For Use With LP Gas. Set Manifold Pressure To 10” W.C And Cleaned Spark Ignition Components As A Preventative Measure. Cycled Unit Several Times To Ensure Proper Operation And Unit Is Heating Properly At This Time.
UNION MILLS, IN
11-08-2021