Furnace Service And Repair Michigan City, Indiana
Call For No Heat. Upon Arrival Found Furnace Giving Pressure Switch Code. After Further Investigation Found Collector Box Water Logged Due To Plugged Condensate Trap. Performed Furnace Service And Clean To Correct Issue. Inspected Primary And Secondary Heat Exchangers Finding No Failures At This Time. Primary Cells Due Have Rust. Inspected Blower Wheel, Evaporator Coil And Air Filter. Cleaned Flame Sensor, Inspected Burners And Crossovers. Cleared Drain Lines, Condensate Trap And Signal Port. Measured Ignitor At 65 Ohms. Cycled Furnace From Thermostat And Observed Operation. Furnace Is Heating At This Time With A Temperature Rise Of 58°. Tested For Carbon Monoxide Finding 0ppm At This Time.
MICHIGAN CITY, IN
01-10-2024
Furnace Service And Repair Michigan City, Indiana
Technician Invoice Notes: Call To Verify Furnace And Zone System Is Operating Properly. Upon Arrival Tested Zone Control System And Found Failed Damper Serving Basement Bedroom Zone. Tall Other Thermostats And Zone Dampers Are Functioning Properly.
Michigan City, IN
01-28-2022
Furnace Service And Repair Michigan City, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Seized Inducer Motor. Replaced Motor Per Customer Request. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 58°. Inspected Heat Exchanger Finding No Failures At This Time.
Michigan City, IN
12-10-2021
Furnace Service And Repair Michigan City, Indiana
Technician Invoice Notes: Call For Furnace Making Boom Noise When Igniting. Observed Ignition Several Times With Rollout Conditions. Inspected Furnace Exhaust Vent And Heat Exchanger Finding No Obstructions Or Failures. Conducted Service And Clean Per Customer Request. Cleaned Burners, Crossovers, Flame Sensor And Spark Ignition. Found Gas Pressure Slightly High. Re Adjusted To 3.5” Water Column. Cleared Inducer Signal Port. Cycled Furnace Multiple Times From Thermostat To Insure Proper Operation. Furnace Is Heating And Operating Properly At This Time. Determined Rollout/boom Was Caused By Delayed Ignition Due To Clogged Burners.
Michigan City, IN
11-30-2021
Furnace Service And Repair Michigan City, Indiana
Technician Invoice Notes: Provided And Installed New Humidifier Solenoid. Cycled Furnace And Tested Humidifier Operation From Humidistat. Adjust Water Supply At Saddle Valve To Insure Proper Operation. Examined Humidifier And Solenoid For Leaks Finding No Leaks At This Time. Humidifier Is Operating Properly At This Time. Set Humidistat To 35%.
Michigan City, IN
10-22-2021
Furnace Service And Repair Michigan City, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Error Code ‘open Limit.’ Found Plugged Air Filter. Pulled Out Air Filter, Customer Will Replace. Checked All Limits And Roll Outs. All Ok. Inspected Furnace Exhaust Termination To Find Pipe Covered With Window Screening Causing Restricted Air Flow. Removed Screening. Plugged Air Filter Plus Vent Motor Limit Being Tripped Due To Screening Covering Exhaust Pipe. Unit Is Heating Properly With A Temperature Rise Of 55 Degrees.
Michigan City, IN
05-04-2021
Furnace Service And Repair Michigan City, Indiana
Technician Invoice Notes: Call To Inspect Sewage Ejection Pump For Proper Operation. Upon Arrival Cycled Pump Several Times To Ensure Proper Operation, Ensured Operation Of The Existing Check Valve And Explained To Client That The Trickling Water Inside The Pump Pit Is Most Likely Condensate Water From Mechanical Room Floor Drain. Client Requests An Estimate For A New Pump Lid And Proper Venting To Be Installed And An Option For A New Sewage Ejection Pump.
Michigan City, IN
03-02-2021