Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Cycled Furnace Upon Arrival And Found Continuous Failed Ignition. After Further Investigation Found Failed Hot Surface Ignitor. Customer Opted To Replace Ignitor. Replaced Ignitor And Tested Operation. Furnace Is Heating Properly At This Time. Inspected Heat Exchangers Finding No Failures At This Time. Found Inducer Housing Leaks Water After Cycle Ends. Customer Opted Not To Have Leak Repaired At This Time.
LAPORTE, IN
04-20-2022
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For Furnace Squealing Upon Start Up. Found Inducer Making Screech Sound When It Starts Up. Customer Would Like Part Replaced. Call With Price And Availability. Returned 2-4-22 And Replaced Failing Inducer Assembly, And Tested Operation. Furnace Is Heating And Operating Properly At This Time. Tested For Carbon Monoxide Finding 0ppm At This Time.
LAPORTE, IN
02-07-2022
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Furnace Attempting To Light And Short Cycling On Low Flame Signal. Clean And Tested Flame Sensor. Cycled Furnace From The Thermostat And It Is Is Heating Properly At This Time With A Temperature Rise Of 44 Degrees.
LaPorte, IN
01-28-2022
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For Furnace Making Intermittent Squeal. After Investigation Determined Squealing Was Coming From Inducer Motor Bearings Wearing Out. Customer Opted To Wait And Think On Replacement. Tested For Carbon Monoxide Finding 0ppm At This Time.
LAPORTE, IN
01-28-2022
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Spark Ignition Cable Shorting Out On Equipment Ground. Wrapped Spark Cable With Electrical Tape As A Temporary Repair. Cycled Unit To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 60 Degrees. Need To Call Client With Price And Availability For A Replacement Igniter Assembly As Soon As Possible.
Laporte, IN
12-02-2021
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Furnace On Rollout Lockout. Reset Rollout Limit And Cycled Furnace. Found Burner Box Overheating. Determined Secondary Heat Exchanger Is Failed. Shut Off Furnace At The Power Switch And Warned Customer Not To Run Furnace. Warned Of The Dangers Of Carbon Monoxide. Will Return At A Later Date To Replace Primary And Secondary Heat Exchangers.
LAPORTE, IN
11-30-2021
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Provided And Installed A New LP Conversion Kit On Maytag Furnace. Replaced Gas Valve Spring And Added Safety Pressure Switch Kit. Set Manifold Pressure To Unit Specifications And Cycled Furnace To Ensure Proper Operation. Unit Is Heating Properly At This Time With A Temperature Rise Of 53°.
LAPORTE, IN
11-30-2021
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Performed Furnace Service And Clean. Inspected Heat Exchangers Finding No Failures At This Time. Inspected Blower Wheel, Evaporator Coil And Replaced Filter. (Left 2 New Filters By Furnace). Cleaned Flame Sensor And Inspected Burners And Crossovers. Cleared Inducer Signal Port, Drain Lines And Trap. Measured Ignitor Resistance At 50 Ohms. Cycled Furnace To Insure Proper Operation. Furnace Is Heating Properly At This Time With A Temperature Rise Of 60°.
LaPorte, IN
10-22-2021
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For Furnace Making Noise. Customer States That Furnace Made A Clinking Sound A Day Ago And Hasn’t Run It Since. Cycled Furnace Several Times To Insure Proper Operation. Listened To Furnace Run And Couldn’t Re-create The Noise. Inspected Primary And Secondary Heat Exchanger Finding No Failures At This Time. Both Blower Motor And Inducer Motor Are Running Within Manufactures Specs. Furnace Is Heating And Operating Properly At This Time With A Temperature Rise Of 59°.
LAPORTE, IN
05-06-2021
Furnace Service And Repair Laporte, Indiana
Technician Invoice Notes: Call For No Heat. Upon Arrival Found Furnace In Ignition Lockout. After Further Investigation Found Failed HSI. Replaced HSI And Inspected Primary And Secondary Heat Exchangers. Found Major Signs Of Heat Exchanger Fatigue With No Confirmed Failures At This Time. Cycled Furnace From The Thermostat To Ensure Proper Operation. Found Blower Motor Bearings Weak Causing Blower Assembly To Vibrate. Unit Is Heating At This Time With A Temperature Rise Of 60 Degrees. Recommended Considering Replacement Of The Furnace In The Near Future Due To Its Age And Condition. Client Requests An Estimate For A Replacement Furnace.
LAPORTE, IN
03-19-2021