La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Two Handle Tub Faucet Cartridges Difficult To Use. Replaced With New 3” Brass Stem Union Gopher Style Cartridges. Also Installed New Easy Use Universal Handles Per Client Request. Tested Operation Of Repair By Cycling Tub Faucet And Observing Proper Operation With No Issues. Informed Client Of Silicone Cure Time.
La Porte, IN
02-07-2022
La Porte, Indiana
Technician Invoice Notes:Upon Arrival Found Toilet To Be Leaking At Base. Pulled Toilet And Found Wax Ring In Bad Condition, Offset Toilet Flange On Concrete Slab, And An Excess Amount Of Wooden Shims Under Toilet Front. Replaced Wax Ring And New Braided Supply Line With New Quarter Turn Stop Valve. Tested Function Of Toilet With No Leaks. After 5 Flushes Toilet Began Backing Up And Slowly Draining. Notified Client That We Will Return On Thursday The 27th With Sewer Equipment To Attempt To Clear The Sewage Line.
La Porte, IN
01-28-2022
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Plumbers Putty Seal Around Pop Up Assembly And Toilet Handle Hitting Toilet Tank Lid Intermittently Sticking To Tank Lid. Removed Existing Pop Up Assembly And Siliconed Properly. Tested By Cycling Water With No Issues. Informed Client Of Silicone Cure Time. Also Replaced Toilet Handle And Positioned Handle Properly. Cycled Toilet Multiple Times To Test With No Issues.
La Porte, IN
01-24-2022
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found 4x3” Furnco Attached Onto 4” Cast Iron Piping Approximately 6”below Floor Grade. Used Necessary Length Of 3” Pvc Piping To Push Down Into Furnco And Into 4” Cast Iron At An Appropriate Depth. Tightened Furnco With 5/16” Band In Crawlspace And Glued On New 3” Pvc Toilet Flange To New 3” Pvc Riser. Secured Flange To Floor. Re Assembled Toilet For Customer Before Resetting And Testing. Cycled Toilet And Observed One Proper Flush. Upon Cycling Toilet For Second Time Observed Backing Up With Improper Drainage. Plunged Toilet In An Attempt To Drain And Conduct A Pull And Reset And Inspect Drainage. While Plunging Observed Toilet Relive Itself And Drain Properly. Cycled Toilet Multiple More Times Amd Observed Proper Drainage At Clean Out Outdoors. Believe Soft Obstruction To Have Been Issue. Explained To Customer How Cast Iron Becomes Porous Internally And Will Continue To Catch Minimal Amounts Of Waste Paper Material Until Replaced. Discussed What To Look For If Sewer Line Starts To Back Up. No Other Issues At This Time.
La Porte, IN
11-15-2021
La Porte, Indiana
Technician Invoice Notes: Investigated And Found Grohe Shower Valve In Too Poor Condition To Disassemble. Shower Stall Constructed Of 1” Granite Walls. Measured And Found Master Shower And Guest Shower Back To Back. Recommend To Client To Have Tile And Wall Removed To Gain Access To Master Valve In Wall.client To Call And Schedule Return When Wall Contractor Sourced And Scheduled.
La Porte, IN
09-13-2021
La Porte, Indiana
Notes: Upon Arrival Found Dishwasher/gas Stove Top/ Gas Oven Appliance Leaking Gas And Nipsco Advised For Appliance To Be Disposed Of. Isolated Gas In Basement Through Existing Gas Cock. Informed Client Of Necessary Gas Piping Needed To Be Stubbed Up Through Flooring And Gas Cock Installed. Discussed In Depth With Client That Since Cabinetry Was Built Around Appliance That Pricing May Increase Do To Cabinetry Coming Down With Appliance Or Being Preemptively Removed In Order To Remove Appliance. Client Wishes To Reschedule So That She Can Be Here While We Are Working.
La Porte, IN
09-13-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Large Amounts Of Debris In Shower Head Screens Causing Low Pressure In Downstairs Shower. Removed Screens And Observed Proper Pressure At This Time. Also Found Sewage Ejection Pump With Suspected Debris On Float. Observed Proper Operation Of Sewage Ejection Pump Several Times Before Informing Client Of Age Of Pump And That We Can Replace. Client Denied At This Time.
La Porte, IN
07-21-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Inspected Toilet With Poor Flush And Found 1.28 Gal Toilet Cycling Correctly When Flushed Correctly. If Toilet Handle Is Pressed Lightly Only Half Flush Occurs. Informed Client Of Findings. Also Conducted Flush And Tune On Navien Tankless Water Heater. Post Flush And Tune Tested Operation Of Water Heater By Cycling Hot Side Of Faucets With No Issues At This Time.
La Porte, IN
07-21-2021
La Porte, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Garbage Disposal And Basket Strainer. Removed Garbage Disposal And Adjacent Basket Strainer. Installed Two New Basket Strainers Along With New Continuous Waste End Outlet Attaching Onto Existing 1 1/2” Pvc . Used Wire Nuts And Electrical Tape To Cover Old Garbage Disposal Wireing, Informed Client That Electrician Will Be Necessary If Old Wiring Is To Be Removed Completely. Tested Operation Of Repair By Cycling Large Amounts Of Water With No Issues At This Time.
La Porte, IN
07-02-2021