Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Found Failed Dual Run Capacitor. Replaced Capacitor And Checked System Amp Draws. A/C Is Cooling Properly At This Time With A Temperature Drop Of 16 Degrees Across The Evaporator Coil. Also Serviced Furnace. Cleaned Burners, Cleaned Flame Sensor, Measured Igniter Resistance At 76 Ohms, Cleaned Inducer Signal Port, Inspected Vent, Inspected Blower Wheel, Inspected Evaporator Coil And Inspected Primary Heat Exchanger Cells. Cycled Furnace To Ensure Proper Operation And Unit Is Heating At This Time With A Temperature Rise Of 47 Degrees.
LAPORTE, IN
09-17-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Call For No A/c. Upon Arrival Found Blower And Outdoor Condenser Fan Operating But Not The Compressor. After Further Investigation Found Shorted Compressor Wire Melted Off The Capacitor. Repaired Wire, Tightened Spade Fittings On Capacitor And Tested Capacitor. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 18°. Also Checked For Proper Air Flow.
LaPorte, IN
07-21-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Call For No A/c. Upon Arrival Found Contactor Not Pulling In When There Was A Call For Cooling. After Investigation Found Chewed And Failed Pressure Switches Inside The Unit. Bypassed Pressure Switches And Test System Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 19° Across The Evaporator Coil. Explained To Customer The Purpose Of Pressure Switches And Offered To Replace If They Chose So In The Future.
LAPORTE, IN
07-21-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Call For No A/c (a/c Not Cooling Properly). Upon Arrival Inspected Blower Wheel, Air Filter And Evaporator Coil. Found Evaporator With Small Amounts Of Remaining Ice, Checked For Proper Air Flow. Upon Further Investigation Found System Low On Refrigerant. Customer Opted To Have System Charged After Explaining There Could Be A Leak. Added 1.5 Pounds Of R22 To System. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 20°.
LAPORTE, IN
07-14-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Call For No A/c. Inspected Air Filter, Evaporator Coil And Blower Wheel. Checked Refrigerant Level Finding System Low On Refrigerant. Customer Opted To Recharge System. Added 2# Of R22 To System. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 20°. Customer Understands There Is A Leak And Would Like Us To Return For A Quote.
LAPORTE, IN
07-14-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Upon Arrival Customer Stated Condenser Fan Won’t Come On With Compressor. Found Weak Capacitor. Customer Opted To Replace Capacitor. Cycled System To Insure Proper Operation.
LAPORTE, IN
06-15-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Call For No A/C. Upon Arrival Inspected Blower Wheel, Evaporator Coil And Air Filter. After Further Investigation Found Failed Condenser Fan Motor And Dual Run Capacitor. Replaced Motor And Capacitor. Unit Is Cooling Properly At This Time With A Temperature Drop Of 17 Degrees Across The Evaporator Coil.
LAPORTE, IN
06-15-2021
Air Conditioning Service, Repair And Installation Laporte, Indiana
Technician Invoice Notes: Upon Arrival Found Disconnect On Condenser Shut Off. Customer Stated She Shuts It Off Every Winter And Forgot To Turn It Back On This Year. Checked System Refrigerant Level. Cycled System To Insure Proper Operation. System Is Cooling Properly At This Time With A Temperature Drop Of 17° Across The Evaporator Coil.
LaPorte, IN
06-15-2021