Water or Steam Boiler Repair

Dye Plumbing & Heatingstarstarstarstarstar4.7 / 5

463 Total Reviews /files/dye-logo-250-130.jpg219-362-6251$1600 Lake Street, LaPorte IN

Water Or Steam Boiler Repair Long Beach, Indiana

If your heating system in Long Beach, IN is not working it is likely your boiler needs repair or a good servicing. At times the fix is simple, at times not. Our heating service technicians have years of experience working on hot water or steam boiler systems like yours in Long Beach, IN. Dye Plumbing & Heating service vehicles are on call 24 hours per day are fully equipped with the tools and parts necessary to get your furnace back up and operating.
Our boiler repair, service or replacement pricing is competitive. Our estimates are always firm with no hidden surprises. You can rely on Dye Plumbing & Heating to advise you properly and to do excellent work promptly.

Get Your Quote Today



Dye Plumbing & Heating Water Or Steam Boiler Repair Long Beach, Indiana



Recent Water Or Steam Boiler Repair Long Beach, Indiana by Dye Plumbing & Heating

starstarstarstarstar
5 Star Rating
Water Or Steam Boiler Repair Long Beach, Indiana
Technician Invoice Notes: Call For Boiler Piping Gurgling And Utilities Bill Very High. Upon Arrival Found Boiler System At Minimal Pressure. Found Expansion Tank Water Logged And Evidence Of Relief Valve Dripping. Also Found Fill Reducing Valve Stuck. Drained System, Replace Relief Valve, Cycled Reducing Valve And Set System Cold Pressure To Approximately 12 PSIG. Bled All Radiation And Cycled Boiler From The Thermostat To Ensure Proper Operation. All Radiation Is Heating Properly At This Time And The Boiler Cycles Off At 170° With A Pressure Of Approximately 20 PSIG. Suspect Clients Utility Bill To Have Been Caused By Short Cycling Of The Boiler Due To Its Low Pressure.
Long Beach, IN
12-13-2021

Water Or Steam Boiler Repair Long Beach, Indiana
Technician Invoice Notes: Call For Air In Boiler System. Upon Arrival Found System Pressure Adequate. Force Purged All Zones Of Air And Cycled Boiler From Every Zone To Ensure Proper Operation. Boiler Cycles Off At 190° With A Pressure Of Approximately 17 PSIG. Client Has An Unsolved Water Leak In Second Story Kitchen Area Causing Wood Flooring To Warp. Client Understands That The Potential Exists For The Boiler Piping To Be The Cause Of The Warped Flooring And The Uncommon Amount Of Air In The Boiler System.
LONG BEACH, IN
11-15-2021

Water Or Steam Boiler Repair Long Beach, Indiana
Technician Invoice Notes: Call For Boiler Relief Valve Dripping. Upon Arrival Found System Near 30 PSIG And Relief Valve Dripping. After Further Investigation Found Failed Reducing Valve. Replaced Reducing Valve And Main Circulator Pump As Part Of Previous Estimate. Filled System To Approximately 12 PSIG And Bled All Radiation. Cycled Boiler From Both Zones To Ensure Proper Operation And System Is Operating Properly At This Time. Boiler Cycles Off At 160° With A Pressure Of Approximately 20 PSIG. Set Thermostats To 67° On Heat Mode And Locked The Home Per Clients Instructions.
Long Beach, IN
11-08-2021

Water Or Steam Boiler Repair Long Beach, Indiana
Scope: Temporarily Shut Down Water Service. Eliminate Dead Piping Near The Main Valve And Install A New 1-1/4 Inch Copper Tee With Isolation And A Drain Above The New Tee For Winterizing The Main Plumbing System. Extend New Piping With A Second Isolation Valve To The Boiler Fill Reducing Valve To Allow Filling Of The Boiler System Independent Of The Home's Main Plumbing System. Repeat This Same Process For The Second Boiler System In The Home. Note: This Proposal Assumes That The Boiler Feed For The Second System Is Also Part Of The Same Main Water Line Under The Slab Of The Home As The First System. This Proposal Includes Boiler Annual Boiler Service, Inspection And Testing After The New Water Lines Have Been Installed.
Long Beach, IN
10-22-2021

Water Or Steam Boiler Repair Long Beach, Indiana
Technician Invoice Notes: Serviced Boiler System. Cleaned Burners, Cleaned Flame Sensor, Cleaned Spark Igniter, Cleaned Pilot Assembly, Inspected Heat Exchanger Sections, Inspected Vent, Inspected Expansion Tank And Cycled Boiler System From The Thermostat To Ensure Proper Operation. Boiler System Is Heating Properly At This Time And The System Cycles Off At 180 Degrees With A Pressure Of Approximately 16 Psi. Client Requests A Mailed Receipt.
LONG BEACH, IN
12-16-2020

Water Or Steam Boiler Repair Long Beach, Indiana
Technician Invoice Notes: Call For No Heat From Boiler System. Upon Arrival Found Boiler Low On Pressure. After Further Investigation Found Reducing Valve Stuck. Adjusted Reducing Valve And Filled System To Approximately 12 Psi And Force Bled Air From Each Zone. Cycled Boiler System From All Three Thermostats And All Radiation Is Heating Properly At This Time. Boiler Cycles Off At 190 Degrees With A Pressure Of Approximately 18 Psi. Recommend Having Boiler Serviced Annually For Preventative Maintenance Purposes.
Long Beach, IN
12-02-2020

©Red Barn Media Group 2024