AC Cooling And Air Conditioning Systems Michigan City, Indiana
Provided Proposal For A New System.
MICHIGAN CITY, IN
08-24-2021
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Installation Details:
EQUIPMENT:
Armstrong A95UH1E045B12S-06; SERIAL 5921A24022 High Efficiency Furnace
- 95% AFUE Efficiency Rating
- Single Stage Heat Operation
- Stainless Steel Heat Exchanger
- Multi-speed High Efficiency Blower Motor
Armstrong 4SCU13LB124P-3; SERIAL: 1620L13474 Outdoor Condensing Unit
- 13 SEER Efficiency Rating (15 SEER As A Packaged System)
- Louvered Jacket Coil Guard Protection
ADP Model: 30BXCA; Serial: 7121E37715 Indoor Evaporator Coil
Honeywell Focus Pro 5000 Non-programmable Thermostat
SCOPE OF WORK:
1. Remove And Dispose Of Existing Furnace, Condensing Unit, Line-set, Condensate Drain Lines And Evaporator Coil.
2. Provide And Install The New Furnace And Evaporator Coil In The Same Location Adapting To The Existing Supply & Return Air Duct Work.
3. Adapt The New Furnace To The Existing Gas And Electrical Circuits Providing A New Outlet/switch Combo.
4. Adapt The New Furnace To The Existing Vent Piping.
5. Provide And Install The New Outdoor Condensing Unit On Wall Brackets Adapting To The Block Wall Of The Home.
6. Adapt The New Condensing Unit To The Existing Electrical Circuit And Service Disconnect With A Field Provided Electrical Whip.
7. Provide And Install New Copper Refrigeration Piping From The Indoor Evaporator Coil To The Outdoor Condensing Unit.
8. Install A New Condensate Pump And Drainage Piping From The New Furnace & Evaporator Coil.
- This New Pump Shall Reside Outside Of The Wall Adjacent To The Chimney Per Clients Request.
9. Provide And Install A New Honeywell Focus Pro 5000 Non-programmable Thermostat In The Same Location As The Existing Thermostat.
10. Start The New Equipment And Check System Operation.
MICHIGAN CITY, IN
07-15-2021
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Technician Invoice Notes: Call For Boiler Only Producing Heat In The Basement Radiation. Upon Arrival Found Boiler At Minimal Pressure And Evidence Of Tridicator Gauge Leaking. Also Found Auto-fill Reducing Valve Failed. Replaced Tridicator Gauge And Reducing Valve. Filled System To 12 PSIG Cold And Purged All Radiation Of Air. Cycled Boiler To Ensure Proper Operation And All Radiation Is Heating Properly At This Time. Boiler Cycles Off At 190° With A Pressure Of Approximately 22 PSIG.
Michigan City, IN
04-14-2020
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Technician Invoice Notes: Upon Arrival Found Failed Basket Strainer On Right Side Of Kitchen Sink. Replaced Basketbstrainer And Tested Operation By Cycling Large Amounts Of Water.
Michigan City, IN
04-11-2020
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Call For Outdoor Faucet Leaking: Rebuilt Outdoor Faucet And Tested Operation.
Michigan City, IN
03-23-2020
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Call For No Hot Water: Replaced Flammable Vapor Sensor For Power Vent Water Heater And Checked Operation.
Michigan City, IN
03-23-2020
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Call For Water Leaking From Furnace: Found Condensate Drain Plugged. Cleared Condensate Drain, Check Refrigerant Levels And System Operation.
Michigan City, IN
03-23-2020
AC Cooling And Air Conditioning Systems Michigan City, Indiana
Replaced Both Incoming And Out Going Sections Of Potable Piping Directly Connected To Water Heater. Installed Dielectric Unions To Prevent Corrosion Of Piping.
Michigan City, IN
03-23-2020